The SR-100 online drug concentration tracer is a highly intelligent industrial online analysis equipment, equipped with multiple sets of signal outputs and independent alarm functions, suitable for outdoor waterproof scenarios. It is easy to operate and stable in operation, providing real-time data support for precise control of drug concentration in circulating water systems. It is widely used for continuous monitoring of circulating water in multiple industries such as power, chemical, and water supply.
★★★★★
Performance Characteristics
- Performance Characteristics
- 144 × 144 intelligent design tracer transmitter
- Provide zero calibration and slope calibration functions for easy on-site application
- Object oriented menu design, easy to operate
- 3 display modes, convenient for users to view various parameters
- 192 × 64 LCD display, soft backlight
- 3 sets of 4-20mA, 3 sets of independent relays
- The watchdog function ensures the normal and continuous operation of the instrument
- Outdoor waterproof type suitable for panel installation and wall installation
Parameters
| Item | Specification |
|---|---|
| Measurement Range | 350A: 0 ~ 99.9 ppmTP: 0 ~ 9.99 ppmTemperature: 0 ~ 50.0 ℃ |
| Resolution | 350A: 0.1 ppmTP: 0.01 ppmTemperature: 0.1 ℃ |
| Repeatability | 350A: ±0.1 ppm |
| Standard Solution | On-site preparation supported |
| Current Output | 3 groups of 4~20mA (photoelectric isolation), load <500ΩOutput current error: ≤±1%FSIndependent parameter matching (350A/TP/OFF) |
| Relay Output | 3 groups of independent relaysMax. AC 220V, 5AIndependent parameter matching (350A/TP/OFF), adjustable hysteresis |
| Display | 192×64 LCD with backlight, 3 display modes |
| Power Supply | AC 90~265V, Power consumption ≤10W |
| Working Environment | Temperature: 0 ~ 60 ℃Relative Humidity: <85% RH |
| Installation Method | Panel mount, Wall mount |
| Protection Grade | IP65 (waterproof & dustproof) |
| Dimensions | Overall: 144×144×120 mm (L×W×D)Cutout: 133×133 mm |
| Net Weight | 0.8kg |
| Communication | 485 communication (for computer monitoring) |
| Special Function | Watchdog function (ensures continuous operation), digital clock |
Matching tracer probe

Core Highlights
- Multi parameter synchronous monitoring: It can simultaneously measure 350A value, TP value, and temperature, meeting the monitoring needs of circulating water agent concentration and environmental temperature in one stop, with real-time data refresh;
- Accurate calibration is convenient: it comes with zero calibration and slope calibration functions, supports on-site adjustment of standard solution, easily completes calibration, and ensures measurement accuracy;
- Rich output and alarm: Standard configuration includes 3 sets of photoelectric isolation 4-20mA current output, 3 sets of independent relays, which can freely match monitoring parameters, and flexible setting of high and low limit alarms;
- Stable, reliable, and long-lasting operation: Equipped with a built-in watchdog function, it effectively prevents program abnormalities, ensures continuous and normal operation of the instrument, and adapts to complex working conditions in industrial sites;
Featured Applications
- Chemical industry: The process of circulating water and cooling water through pipes in chemical industrial parks, as well as managing the chemical concentration accurately to stop equipment from corroding and scaling.
- Water supply: circulating water systems in sewage treatment facilities and waterworks; keeping an eye on the quantities of water purification agents to make sure treatment is as effective as possible;
- Pharmaceutical and food production workshops use circulating water to check the concentration of drugs, meet cleanliness and process standards, and more.
- Smelting, the paper mill’s circulating water system, managing chemical concentrations in real time, and lowering the cost of operating and maintaining equipment.

Daily maintenance and precautions
Installation and usage precautions
- Before installing the instrument, it is necessary to cut off the power and choose a dry and non corrosive place. The panel installation should have a 133 × 133mm hole in the control cabinet and be firmly fixed;
- Strictly follow the terminal instructions when wiring, connect the power, output, and sensor circuits separately, and ensure proper grounding to prevent interference;
- The sensor needs to be correctly connected to the power supply and signal line, and the calibration operation should be completed before use to ensure accurate measurement data;
- Regularly check the operation status of the instrument, clean the display screen, and if there is any abnormal data, recalibrate or check the circuit connection.
Maintenance and guarantee
- Daily maintenance does not require professional operation. Regularly check whether the wiring is loose, whether the instrument housing is intact, and keep the display screen clean;
- If the measurement accuracy decreases after long-term use, zero and slope calibration can be performed again to restore the measurement accuracy;
- The product provides comprehensive technical support, accompanied by detailed operation manuals. For complex issues, please contact the manufacturer’s professional personnel for answers.
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
The SR-100 online drug concentration tracer is different from others since it has a lot of functions, is very accurate, and is stable. It may be set up and utilized in any industrial setting, and it can monitor, output, and sound alarms. It provides a dependable and effective way to keep an eye on things online to lessen worries about equipment rust and scaling, boost operational efficiency, and control the levels of tiny medicines in water systems that are used in a wide range of sectors.
Request a Quote
.png)