F34-1020 is an industrial online fluoride ion electrode, based on ion selective potential method, accurately measuring 0.20-2000 ppm F ⁻. It adopts a fluorine single crystal membrane and solid electrolyte design, with pressure resistance and pollution resistance, suitable for 0-80 ℃ and 5.00-10.00 pH environment, and installed in 3/4 “NPT. It is widely used in wastewater monitoring in semiconductor, metallurgical and other industries.
★★★★★
Features
- The online fluoride ion composite electrode is composed of a fluoride single crystal membrane, a polytetrafluoroethylene annular liquid interface, and a solid electrolyte composite, and has characteristics such as pressure resistance and pollution resistance;
- Widely used in the fields of wastewater treatment process control and emission monitoring in semiconductor materials, solar materials, metallurgical industry, fluorine-containing electroplating and other industries.
Parameters
| Category | Specifications |
|---|---|
| Measurement Principle | Ion-selective potentiometry |
| Measurement Range | 0.20-2000 ppm F⁻ |
| Electrode Slope | 56±mV @ 25℃ |
| Accuracy | Dependent on matching meter (compatible with Apure RB-2084S/INO10-SA1 etc.) |
| Response Time | ≤2 mins (@ ≥2 ppm F⁻); ≤1 min (@ ≥20 ppm F⁻) |
| pH Range | 5.00-10.00 pH |
| Temperature Range | 0-80℃; Temperature Sensor: PT1000 (customizable: PT100/10K/30K/2.252K) |
| Interfering Ions | Al³⁺, Fe³⁺, OH⁻ etc. |
| Blank Potential | >180 mV (@ deionized water) |
| Construction | POM body; Fluoride single crystal membrane; PTFE liquid junction; Solid electrolyte |
| Physical Specifications | Length: 168mm; Diameter: 22mm; Mounting Size: 3/4″ NPT |
| Application Scenarios | Semiconductor manufacturing, solar energy materials, metallurgy, fluoride electroplating, wastewater monitorin |
Core Highlights
- Rapid response: response time ≤ 1 minute under high concentration fluoride ions (≥ 20 ppm), meeting the timeliness requirements of industrial online real-time monitoring;
- Wide adaptability: compatible with temperature range of 0-80 ℃ and pH environment of 5.00-10.00, can be used with instruments such as Apure RB-2084S/INO10-SA1, and is suitable for multi scenario monitoring systems;
- Easy installation: 3/4 “NPT standard installation size, length 168mm, can adapt to various installation methods such as flow type and pipeline type, simple wiring and easy operation;
- Strong durability: The POM material electrode body is pressure resistant and corrosion-resistant, and the solid electrolyte design reduces the risk of leakage and extends its service life.
Featured Applications
- Semiconductor manufacturing: keeping an eye on the fluoride ion leaks from production waste to make sure that environmental rules are followed in the electronics industry;
- Making solar materials: keeping an eye on the concentration of the fluorine-containing process solution in real time and changing the parameters of the production process;
- Control the amount of fluoride ions in mining wastewater to keep soil and water from getting damaged;
- Fluorine plating: Control the amount of fluoride ions in the plating solution to make sure the quality of the coating and the security of the process.

Daily maintenance and precautions
Installation and Wiring
- Installation method: 3/4 “NPT thread installation is used, which can be matched with accessories such as flow slots and pipeline flanges to ensure that the electrode membrane is completely immersed in the tested solution;
- Wiring specifications: When stripping, the metal wire layer should be stripped off, and the conductive rubber on the outer layer of the transparent central axis should be removed. The temperature line (yellow/red) corresponds to the instrument TEMP ± terminal. The metal wire and the transparent central axis should be connected to the instrument signal terminal separately, and the wiring should be waterproofed;
- Installation precautions: Avoid collision between electrodes and hard objects to prevent damage to the fluorine single crystal film; Stay away from strong magnetic field interference to ensure stable measurement signals.
Maintenance, calibration
- Recommended calibration frequency: 1-2 times per week. Before calibration, clean the electrode with deionized water until the blank potential exceeds 200mV;
- Calibration method: Paired with corresponding equipment (RB-2084S), utilize two-point or multi-point calibration and reference fluoride ion solutions (1ppm, 100ppm) to cover the measurement range;
- Daily cleanup: As usual, rinse with tap water; If there are calcium deposits on the membrane, wash it in 5-10% hydrochloric acid for 10 minutes, rinse it, and soak it in 3M KCl for more than 10 minutes; clean oil stains with detergent;
- Special care: suede bathed in polishing powder can lightly polish tough stains that hydrochloric acid cannot remove. It is forbidden to scrape the film with harsh objects; Maintain in 3M KCl solution when not in use and avoid pure water for long periods.
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
F34-1020 fluoride ion electrode stands out as a reliable choice for industrial fluoride monitoring, boasting precise measurement, contamination resistance, and rapid response. From semiconductor manufacturing to environmental water treatment, it fully adapts to complex working conditions. When paired with Sino-Inst’s series of meters, it forms a complete monitoring system, providing stable sensing support for process optimization and compliance with emission standards.
Request a Quote
.png)