The GRT1130-K9 pH sensor is a high-temperature wastewater and complicated media “anti manufacturing monitoring officer”! Electrodes can be “poisoned” by ions, blocked by contaminants, or unable to sustain high temperatures, making maintenance laborious and expensive for online detection of high-temperature wastewater, colloidal media, or poisonous ions like S ² ⁻ and CN ⁻. The gel electrolyte salt bridge and high-temperature two-point ceramic core fluid interface are anti-virus, anti-blocking, and temperature-resistant. The electrolyte-free system reacts immediately. Its standard interface and double connector design make it ideal for high-temperature sewage monitoring and makes complex operating circumstances easy to measure.
★★★★★
Features
Specifications
| Parameter | Value |
|---|---|
| pH Range | 0-14 |
| Temperature Range | 0-100℃ |
| Pressure Range | 0-0.3 M Pa |
| Zero potential | 7±0.5 |
| Theoretical percentage slope | ≥ 95% |
Core strength
- Antitoxic without failure: special gel electrolyte salt bridge design can effectively resist the corrosion of toxic ions such as S ² ⁻ and CN ⁻, and avoid electrode poisoning
- Anti blocking and high temperature resistance: High temperature two-point ceramic core liquid interface, not easily blocked by impurities in sewage, can be detected online for a long time in a high temperature environment of 0-100 ℃
- Maintenance free and convenient: special gel electrolyte is pre charged at one time, and there is no need to supplement the whole process, greatly reducing the on-site operation and maintenance workload
- Stable and fast response: The electrode has low internal resistance, and when facing high-temperature wastewater and colloidal media, the data response is fast and stable, with a zero potential of 7 ± 0.5mV
- Wide installation adaptability: standard PG13.5 thread, supports pipeline installation or sleeve matching, compatible with various acidity meters
- Dual compatibility of connectors: using BNC standard connectors or pin type wiring terminals to adapt to different device interfaces without the need for additional adapters
Adaptation scenario:
- Online monitoring of high-temperature wastewater: continuous monitoring of pH in industrial high-temperature wastewater and biochemical treated high-temperature wastewater, with anti toxic and anti blocking design to deal with toxic ions and suspended impurities in water;
- Colloidal medium measurement: Accurately measure the pH value of various colloidal raw materials and colloidal chemical wastewater. The special sensitive membrane material avoids medium adhesion and measurement does not drift;


- Monitoring of toxic ion media: capable of dealing with industrial wastewater containing S ² ⁻, CN ⁻ and other substances that are prone to electrode poisoning. Salt bridges effectively isolate toxic ions and extend their service life;
- Conventional industrial monitoring: pH monitoring of conventional high-temperature conditions in industries such as chemical, metallurgical, printing and dyeing, compatible with pipeline installation or container installation, and suitable for continuous production needs;
Maintenance
- Daily cleaning: Rinse the electrode with distilled water before and after measurement, gently absorb moisture with filter paper to avoid residue of viscous media;Deep cleaning once a week to clear the liquid interface;
- Sediment treatment: When the glass film appears semi transparent or adhered, soak it in dilute hydrochloric acid for 5-10 minutes, rinse with clean water, and do not scratch it with hard objects;
- Idle storage: After washing, put on a protective cover containing 3.3Mol/L KCL solution and place it in a dry and ventilated place. Dry storage is strictly prohibited from causing the sensitive film to fail;
- Regular calibration: It is recommended to calibrate once a week with standard calibration solution to ensure measurement accuracy; In scenarios with high levels of viscous media or impurities, calibration can be shortened to every 3-4 days;
- Taboo: Avoid long-term immersion in distilled water, protein solutions, or acidic chloride solutions, stay away from organic silicon oils and fats, and prevent electrode performance degradation.
Sensor diagram illustration

- After opening the packaging, check whether there is mechanical damage to the sensitive bulb and electrode body of the sensor.
- Remove the sensor protective cover and check if there are any bubbles in the sensitive bulb of the electrode. If so, gently shake the electrode in a vertical plane to remove the bubbles;
- Select the corresponding sensor sleeve or cable head for installation according to different sensors;
- The connection between the sensor wire and the electrode is not waterproof, please make sure to do a good job of waterproofing.
Wire stripping instructions

Attention
- The outer layer of the transparent central axis is covered with a conductive rubber layer and a metal mesh layer. When stripping, first strip the metal mesh layer into the metal mesh as shown in the picture, and be sure to removal of conductive black skin on the transparent central axis;
- The cable extends to the host without any contact points except for a dedicated junction box.
Technical Support
5 Best carbon monoxide detector for garage
10 Best carbon monoxide monitor for industrial use 2025
7+ Best Recommended Carbon Monoxide Detector for Industrial Use
What Is pH in Water? A Complete Guide to Understanding (2026)
6 Types of Industrial Oxygen Sensors
6 Best Industrial Gas Detector Manufacturers in the World
The GRT1130-AS7 pH electrode, with its core advantages of “dual interface universality, multi degree adaptation, and anti blocking and maintenance free”, perfectly solves the adaptation problems and blockage pain points in viscous medium monitoring. From continuous monitoring of sewage treatment to process control in the electroplating industry, from production of viscous media to replacement of imported equipment, it can flexibly adapt and stably output accurate data. The flexible configuration of dual interfaces, multiple lengths, and dual sheaths not only reduces the cost of replacing imported electrodes, but also meets the installation needs of different scenarios.
Consultation now provides exclusive selection solutions, installation guidance, and maintenance skills, allowing complex media pH measurement to bid farewell to adaptation and blockage troubles, and helping production processes operate efficiently and quality control be accurately implemented!
Request a Quote
.png)