The A30PR is a high-grade pH and ORP controller for industrial settings that need to keep an eye on water quality all the time. The A30PR has a strong design that lets it monitor pH levels with an accuracy of ±0.01 pH in the range of 0 to 14 pH and ORP levels from -2000 to +2000 mV.
The A30PR is accurate, dependable, and adaptable for wastewater treatment, the chemical industry, food processing, and aquaculture systems that keep water quality high. The A30PR is easy to use for people of all skill levels because it has a menu-driven interface and can be calibrated at two or three points.
★★★★★
Features
Specifications
| Measuring range | pH(0—14 pH,0.0—14.0 pH,0.00—14.00 pH ) ORP( -1999 — +1999 MV) |
| Accuracy | ±0.01 pH; ±1 mV |
| Resolution | 0.01 pH; 1 mV |
| Stability | ≤ 0.02 pH/24 hours; ≤ 3 mV/24 hours |
| Temperature Compensation | 0–100 °C Manual / Automatic (PT1000/NTC10K) |
| Signal Output | 4–20 mA isolated protection output, independently corresponding to pH/ORP or temperature, with a load capacity up to 500Ω |
| Alarm Output | Two sets of high/low point alarms (3A/250 V AC) normally open contact relay, one set of self-cleaning |
| Power Supply | AC220V or DC24V |
| Power Consumption | ≤ 7 W |
| Environmental Conditions | Temperature: 0–60 °C; Humidity ≤ 85% RH |
| Overall Dimensions | 46× 96× 110 mm (Height × Width × Depth) |
| Opening Size | 42 × 90 mm (height × width) |
Where can it be used
Treatment of sewage
Stage of application
- Inlet pH monitoring: Real time monitoring of raw water pH to protect subsequent treatment equipment
- Biochemical pool pH regulation: maintain the optimal living environment for microorganisms (pH 6.5-8.5) and improve treatment efficiency
- Monitoring of effluent compliance: ensuring that the discharged water quality meets environmental standards

Chemical production
Stage of application
- Kettle for reactions pH control: exact control of the circumstances under which chemical reactions happen
- Monitoring of the neutralization tank: control of the process for treating acid-base waste liquids
- Circulating cooling water: stops pipes from corroding and building up scale
Food and Beverage
Application stage
- CIP cleaning monitoring: confirm the completion of each stage of alkali washing, acid washing, and rinsing
- Fermentation process control: real-time monitoring of fermentation pH for beer, yogurt, etc
- Boiler feedwater: prevent equipment corrosion

Electroplating surface treatment
Application stage
- PH control of electroplating bath solution: affecting the quality of coating
- Monitoring of pre-treatment degreasing and acid washing processes
- Neutralization tank for wastewater treatment
Guide for Selecting Temperature Compensation Methods
When choosing PT1000:
Process temperature range>20 ℃ (e.g. 5-60 ℃)
High precision temperature compensation is required (actual temperature within ± 0.5 ℃)
Outdoor installation or large seasonal temperature difference
Typical applications: sewage treatment, chemical reaction kettle
When choosing NTC10K:
Relatively stable temperature (within ± 10 ℃)
Cost sensitive projects
Normal temperature condition (15-35 ℃)
Typical applications: CIP for food, swimming pool water quality, aquaculture
When choosing manual compensation:
Laboratory constant temperature environment
Temperature change<5 ℃
Limited budget and low precision requirements
Typical applications: school training, small aquariums
Comparison of Core Differences
Comparative dimension2814_20481c-f7> |
A10PR2814_2f4b3d-2e> |
A20PR2814_1e69d0-9f> |
A30PR2814_e407f6-0b> |
|
Core positioning 2814_8122c1-f8> |
Basic industrial grade, cost-effective universal model 2814_0115c1-2d> |
Multi functional advanced model, flexibly adaptable to complex scenarios 2814_aea8f4-0b> |
Compact and space saving design, focusing on small size requirements 2814_cf9909-1e> |
|
Overall Dimensions 2814_e208e8-dd> |
96×96×128 mm 2814_b7da01-02> |
144×144×115 mm 2814_616ba1-07> |
48×96×110 mm 2814_c15077-d1> |
|
Installation method 2814_7f5e74-3d> |
Panel mounted 2814_cdd57c-4a> |
Panel mounted and wall mounted dual-mode 2814_6f2a97-4b> |
Panel mounted(requiring only 42 × 90 mm openings) 2814_3dc6b4-0a> |
|
Relay configuration 2814_19f41e-85> |
Three groups (freely switch between high and low points) 2814_93da34-68> |
Three groups (supporting 8 modes including in/out of range and time control) 2814_0ab844-11> |
One set (high and low point switching, adjustable hysteresis) 2814_8bf872-6e> |
|
Signal output 2814_e8b767-4e> |
1 channel 4-20mA (optional RS485) 2814_18044f-7c> |
2-channel 4-20mA (independently corresponding to pH/ORP/temperature, optional RS485) 2814_dcf044-3d> |
1 channel 4-20mA (only corresponding to pH/ORP, optional RS485) 2814_bc15db-e8> |
|
Protection level 2814_0ce647-2f> |
– 2814_90e62e-a9> |
– 2814_818f99-43> |
IP54(dustproof and moisture-proof) 2814_c9ea33-7d> |
|
Applicable scenarios 2814_0c8a9e-b3> |
Basic monitoring of small and medium-sized sewage stations, swimming pools, aquaculture, etc 2814_4004a4-1e> |
Complex working conditions such as chemical, pharmaceutical, and municipal wastewater require synchronous output of multiple parametersV 2814_139aa0-d9> |
Small production lines, laboratories, and control cabinets in beverage factories with limited space 2814_8d54f1-50> |
|
Power consumption 2814_5dbc30-e7> |
≤ 7 W 2814_96d748-e0> |
≤ 5 W 2814_34f9f2-73> |
≤ 7 W 2814_ee350b-6d> |
Comparison of two communication methods
| Application scenarios | A20PR Advantages | Common products |
| Chemical workshop (high interference) | Isolation output+dedicated cable, data fluctuation ≤ ± 0.02pH/24h | Vulnerable to electromagnetic interference and large data drift |
| Municipal wastewater treatment plant (humid environment) | Waterproof junction box+leak proof installation, no risk of short circuit | The wiring is prone to moisture and has a high failure rate |
| Multinational factories (multilingual requirements) | One click switching between Chinese and English, with no communication barriers during operation | Need to restart the device to switch, the process is cumbersome |
| Novice operator (non professional) | Menu preview+prompt function, calibration completed in 3 steps | The menu hierarchy is complex and prone to incorrect operation |
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
A30PR integrates unparalleled precision (0.01% pH accuracy) into a compact 96x96mm design, providing certain advantages in areas where large units cannot be installed. With the sturdy IP54 dust and moisture resistance, reliable alarm dual relays, and anti-interference dedicated 4-20mA signal, chaotic industrial environments have been transformed into predictable and compatible spaces.
No need to explore complex settings or sacrifice performance for size – A30PR provides everything: reliability, accuracy, and simplicity. Whether it’s wastewater treatment or chemical production, A30PR is your best choice!
Request a Quote
.png)