The ION10 online ion concentration meter, designed for industrial use, can reliably monitor ion concentrations in aqueous solutions (0~99999mg/L, electrode-specific). The power plant, petrochemical, metallurgical electronics, environmental water treatment, food and beverage sectors, and others use it. The differential signal measuring mode, IP65 protection, and disk and wall mounting provide a solid solution for continuous ion concentration monitoring and control in industrial production processes.
★★★★★
Features
- Dot matrix LCD screen display, intelligent menu operation
- Multiple automatic calibration functions, multiple signal output methods
- Manual and automatic temperature compensation
- Two/three sets of relay control switches, high limit, low limit, hysteresis control
- Display ion concentration, temperature, status, etc. on the same interface
Parameters
| Category | Specifications |
|---|---|
| Measurement Principle | Differential signal measurement; Ion selective electrode (ISE) principle |
| Range & Accuracy | Ion concentration: 0~99999mg/L (depending on electrode); Error: ±2%; Resolution: 0.01/0.1/1mg/L |
| Temperature Performance | Range: 0~80.0℃; Error: ±0.3℃; Resolution: 0.1℃; Compensation: Auto/Manual (0~80.0℃) |
| Stability | Weekly drift <2%F.S (normal temperature and pressure) |
| Output & Communication | 1 standard 4-20mA output (2 optional, load resistance <500Ω); RS485 Modbus RTU |
| Relay Control | 2 groups (3A 250VAC, 3A 30VDC); High/low limit & hysteresis control |
| Power Supply | 85~265VAC or 9~36VDC (optional); Power consumption: <3W |
| Physical Specifications | Dimension: 98×98×130mm; Mounting hole: 92.5×92.5mm; Weight: ~0.6kg; Protection class: IP65 |
| Operating Environment | Temperature: -10~60℃; Relative humidity: ≤90%; No strong magnetic interference |
Standard Configuration
- Host: INO10-SA1
- F-Electrode: KS-F-20.0-5M

KS-F-20.0-5M Technical Specifications
| material | PPS |
| measurement range | 0—20,000ppm |
| pressure resistance | 3bar |
| heat-resistant | 0—50℃ |
| PH range | 5—7PH |
Core Highlights
- The differential signal measuring method is precise and reliable, with a fundamental error of ± 2% and a weekly drift of <2% F.S, resisting interference and yielding reliable findings.
- Easy to use: The LCD panel displays ion concentration, temperature, and operational state, with an intelligent menu and password protection to prevent accidental operation;
- Flexible calibration provides multi-point (5 bespoke) and on-site calibration, stores calibration data, and adapts to concentration;
- Multi-output RS485/4-20mCurrent output, two relay sets control high and low limits for central control and dosing systems;
- IP65 waterproof and dustproof, disk-mounted (embedded) and wall-mounted, small body, suitable for tough industrial situations;
- The measurement instrument may switch between mg/L and ppm and employ many ion electrodes for multiple industries’ ion monitoring needs.
Featured Applications
- Industrial production: monitoring the ion concentration of production process fluids in the chemical, metallurgical, and electronic industries to prevent equipment corrosion and scaling;
- Environmental water treatment: Compliance testing for the discharge of specific ions (such as fluoride ions and heavy metal ions) in the inflow and outflow of sewage treatment plants;
- Energy and electricity: Real time monitoring of ion concentration in circulating water of power plants to ensure stable operation of generator units;
- Food and medicine: quality control of ion concentration in water used for food and beverage production and pharmaceutical fermentation processes;

Daily maintenance and precautions
Key usage precautions
- Electrode maintenance: Avoid pulling the electrode cable, regularly clean the surface attachments of the electrode, and use the same electrode for calibration and measurement to ensure accuracy;
- Standard sample requirements: The concentration of the standard sample should be set in descending order, and the manually entered standard value should not be less than the previous calibration point. Diluted standard samples should be prepared as needed;
- Environmental requirements: Avoid placing the instrument in high temperatures, strong magnetic fields, or humid environments that may affect measurement stability;
- Password management: Passwords can be set in the “System Settings” to prevent unauthorized operations, and there is no password by default at the factory.
Maintenance and Care
- Cleaning the instrument casing and checking wiring terminals for oxidation daily; Weekly check electrode condition and wipe surface debris;
- Regular calibration: Zero point calibration should be done monthly and full range multi-point calibration every three months;
- The power supply and wiring should be checked first if the LCD does not light up or produce current. If it’s unsolvable, contact the manufacturer’s after-sales assistance. Don’t disassemble it yourself;
- When not in use, disconnect the power supply, store the electrodes, stow the instrument in a dry, ventilated environment, and recalibrate before reuse.
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
You may use ION10 ion meters in many various places to measure the amount of ions because they are accurate, reliable, and easy to use. It includes a lot of installation options, output interfaces, and excellent protection, so businesses can use it to keep an eye on the quality of their industrial water and improve their operations. Keeping an eye on businesses and following environmental standards doesn’t cost much.
Request a Quote
.png)