DDB-305A is a portable conductivity controller that can be used in mobile scenarios. It can swiftly measure the conductivity, TDS, and temperature of water-based solutions. The instrument is equipped with a 3.5-inch high-definition LCD display screen, with IP65 high protection level, built-in large capacity lithium battery, and supports long-term work in mobile environments such as outdoor and on-site.
Adapting to the on-site testing needs of various fields such as petrochemicals, biomedicine, sewage treatment, environmental monitoring, and university research, with functions such as automatic standard solution recognition, dual-mode temperature compensation, and massive data storage, we provide stable, efficient, and convenient solutions for mobile measurement.
★★★★★
Features
Conductivity Controller Specifications
| Category | Specifications |
|---|---|
| Instrument Class | Class 1.0 |
| Measurement Range | Conductivity: 0.00μS/cm ~ 200mS/cm (auto frequency switching, full-range coverage)TDS: 0.00mg/L ~ 100g/LTemperature: -5.0℃ ~ 110.0℃ |
| Measurement Accuracy | Conductivity/TDS: ±1.0% F.STemperature: ±0.2℃ |
| Resolution | Conductivity: 0.01μS/cmTDS: 0.01mg/LTemperature: 0.1℃ |
| Temperature Compensation | Dual mode: Automatic (ATC) / Manual (MTC); default temperature coefficient 2.00%/℃ |
| Calibration Function | Auto-recognizes 4 types of GB standard conductivity solutions; supports 1-point calibration |
| Data Storage | Supports storage, review, and deletion (single/all) of 200 sets of measurement results |
| Power Supply | Built-in large-capacity lithium battery; supports charging via MicroUSB (PC or power bank); comes with 5V 2A dedicated charger |
| Power-related Features | Low battery reminder, real-time charging status display; auto-shutdown (energy-saving design) |
| Physical Parameters | Dimensions: 80×225×35mm (H×W×D)Weight: Approx. 0.4kgProtection Class: IP65 (dustproof and waterproof) |
| Operation Functions | Dual measurement modes (continuous/balanced); backlight adjustment; power-off protection; factory reset |
| Power Input/Output | Input: AC100-240VOutput: DC5V |
| Operating Environment | Ambient Temperature: 0~40℃Relative Humidity: ≤85% (no strong magnetic interference) |
Standard Configuration
- DDB-305A portable conductivity meter
- DJS-1VTC type conductive electrode
- HW-050200C01 charger 5V 2A
- Electrode hanger
- MicroUSB cable
- Protective cover (installed on the host)
- Portable protective box
- Easy operation guide
- Instruction Manual
- Product Qualification Certificate
Core Highlights
- Long battery life: It has a huge lithium battery that can charge mobile devices, lasts a long time outside, and delivers real-time warnings when the battery is low or charging.
- High protection: The IP65 rating means it may be used in wet and muddy environments, and the protective cover for the instrument makes it even more robust.
- ± 1.0% F.S. measurement accuracy, automatic identification of reference solution makes calibration easier, and dual measuring mode works for a variety of situations.
- The 3.5-inch high-definition LCD screen is easy to use because the buttons are clear to see. You can also vary the lighting, which makes it simple to read at night.
Featured Applications
- Field environmental monitoring: on-site conductivity testing of surface water, groundwater, and soil leachate.
- Sewage treatment site: Rapid monitoring of water quality in each process section of the sewage treatment plant, without the need to bring it back to the laboratory.
- Industrial site inspection: spot checks on water quality at production sites in industries such as petrochemicals and mining smelting.
- Biopharmaceutical site: rapid on-site quality inspection of water and biologics used in pharmaceutical workshops.

Daily maintenance and precautions
Maintenance points
- Electrode maintenance: After the first use or long-term idle, it needs to be immersed in distilled water for several hours; Organic stains should be cleaned with warm water or alcohol containing detergent. Calcium and magnesium precipitates should be treated with 10% citric acid. Mechanical scrubbing of platinum black electrodes is prohibited.
- Instrument maintenance: Clean the shell with a damp cloth to avoid contact with strong acids and alkalis; When not in use for a long time, it needs to be fully charged before storage, and recharged every 3 months to extend the battery life.
- Calibration cycle: It is recommended to calibrate every 3 months, and shorten it to 1-2 months for frequent use or harsh outdoor environments.
Safety precautions
- Only use the standard power adapter of the instrument to avoid equipment damage caused by voltage mismatch.
- The electrode plug should be kept dry and clean, avoiding contact with acid, alkali, and salt solutions to prevent short circuits or measurement errors.
- When using outdoors, avoid dropping or colliding the instrument, and wipe off the moisture on the outer shell in a timely manner after use on rainy days.
- Do not disassemble the instrument or battery by yourself. Contact the official after-sales service for assistance in case of malfunction.
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
The Thunder Magnetic DDB-305A portable conductivity controller is “portable, accurate, and long-lasting.” It works well for monitoring in the field and on site. It can assess outside scientific investigations, industrial site inspections, and emergency sewage treatment testing faster and more accurately than a lab. A transportable water quality monitor that is light, durable, and tough is easier to use and works better.
After the sale, you can get expert technical help and service. If you need help using, replacing parts, or fixing a problem, please call our official customer service.
Request a Quote
.png)