DDS-307A conductivity controller is designed for laboratory use. It can correctly check the temperature, conductivity, and TDS of the liquid mainly composed of water. Its protection level is IP54, which means it can resist dust and water, and it also has a 6.0-inch high-definition LCD screen. It can be used to check water quality in biomedical, petrochemical, wastewater treatment, environmental tracking, and academic fields. It can save and retrieve data, immediately identify common issues, and allow you to change the temperature twice. This device is stable, reliable, and easy to measure in research.
★★★★★
Features
Conductivity Controller Specifications
| Category | Specifications |
|---|---|
| Measurement Range | Conductivity: 0.00μS/cm ~ 200mS/cm (auto-switchable multi-range)TDS: 0.00mg/L ~ 100g/LTemperature: -5.0℃ ~ 110.0℃ |
| Measurement Accuracy | Conductivity/TDS: ±1.0% F.STemperature: ±0.2℃ (0.0℃~60.0℃); ±1.0℃ (other ranges) |
| Resolution | Conductivity: 0.01μS/cm (auto-switchable by range)TDS: 0.01mg/L (auto-switchable by range)Temperature: 0.1℃ |
| Temperature Compensation | Dual mode: Automatic (ATC) / Manual (MTC); default temperature coefficient 2.00%/℃ |
| Calibration Function | Auto-recognizes 4 types of GB standard conductivity solutions (111.3mS/cm, 12.85mS/cm, 1408μS/cm, 146.5μS/cm); supports 1-point calibration and custom standard solution calibration |
| Data Storage | Supports storage, review, and deletion (single/all) of 50 sets of measurement results |
| Operation Functions | Dual measurement modes (continuous/balanced); auto-shutdown (adjustable 300~3600Sec); power-off protection; factory reset |
| Power Supply | Input: AC100-240V; Output: DC9V/800mA power adapter (inner positive, outer negative) |
| Physical Parameters | Dimensions: 242×195×68mm (H×W×D)Weight: Approx. 0.9kgProtection Class: IP54 |
| Operating Environment | Ambient Temperature: 0~40℃Relative Humidity: ≤85% (no strong magnetic interference) |
Standard Configuration
- DDS-307A conductivity meter
- DJS-1VTC type conductive electrode
- REX-5 multifunctional electrode holder
- YW-18W power adapter DC 9V (positive inside and negative outside)
- Dust cover (button type)
- Easy operation guide
- Instruction Manual
- Product Qualification Certificate
Core Highlights
- Easy to operate: high-definition LCD display, intuitive button operation; Support continuous/balanced dual measurement mode, long press the shortcut key to quickly switch functions.
- Durable protection: IP54 dustproof and waterproof rating, the shell is resistant to contamination by conventional chemical reagents, and suitable for complex laboratory environments.
- Practical function: 50 sets of data storage, complete automatic shutdown and power-off protection functions, meeting the needs of experimental data traceability and instrument energy saving.
- Wide adaptability: Equipped with a K=1 platinum black electrode, it supports adaptation to multiple electrode constants ranging from 0.01 to 10, covering measurements of low, medium, and high conductivity samples.
Featured Applications
- University research: laboratory water quality analysis, solution characteristics research and other experimental teaching and research projects.
- Chemical industry: purity testing of raw materials, monitoring of water quality changes during reaction processes.
- Biopharmaceuticals: Purity control of pharmaceutical water, detection of conductivity of biological agent solutions.
- Environmental monitoring: analysis of sewage sample quality, detection of surface water/groundwater conductivity.
- Other fields: Laboratory water quality routine testing in industries such as mining and smelting, food and beverage.

Instructions for installing and using
A few quick steps for installation
- Putting the instrument together: it is set in the instrument cabinet or box, out of direct sunlight and water, and wired for power (but not turned on).
- Electrode installation: It lets you put electrodes in a number of different ways, such as the flange type, the three-way type, the immersion type (with bracket), and others, to make sure that the electrode touches the solution completely.
- Connecting the wires: Connect the electrode terminals one at a time, paying attention to the marks on the instrument and the color of each one. There are rules about how to connect the power and signal lines, and the ground wire needs to be properly grounded.
- Settings for power on: Plug in the power, go to the parameter menu, check the parameters based on the electrode constant and measurement range (which are specified at the factory), and then go to the measurement state after you’re done.
Safety precautions
- Only use the standard power adapter of the instrument to avoid equipment damage caused by voltage mismatch.
- The electrode plug should be kept dry and clean, avoiding contact with acid, alkali, and salt solutions to prevent short circuits or measurement errors.
- Prohibit the use of instruments in flammable and explosive environments to avoid liquid infiltration into the interior of the instrument and causing malfunctions.
- When the instrument is damaged or unable to measure normally, please do not disassemble it by yourself and contact after-sales maintenance in a timely manner.
Technical Support
Top 6 Industrial Gas Analyzers Manufacturers 2025
6 Best Industrial Gas Detector Manufacturers in the World
9 Best Portable Carbon Dioxide Detector 2025 – Complete Buying Guide
Top 7 portable combustion analyzer Tested
The DDS-307A laboratory conductivity meter is designed with precision, convenience, and durability as its core concepts, integrating practical functions for multi scenario adaptation and reliable protective performance. Whether it is routine testing or scientific research experiments, it can provide stable measurement data and efficient operation experience, helping users simplify the experimental process and improve work efficiency.
We provide professional technical support and after-sales service. If you need selection consultation, operation guidance, or accessory procurement, please feel free to contact our official customer service for exclusive assistance!
Request a Quote
.png)